Patient Monitor HM11 - Parameter

Standard parameters DOWNLOAD FILE

ECG:

Lead selection: three/five lead standard; up to 7 leads can be displayed on the same screen

I, II, III, AVR, AVL, AVF, V chest leads

ECG detection range: 15~350bpm

Resolution: 1bpm

Measurement accuracy: the greater of ±2% or ±2bpm

Frequency Response: 0.67Hz-40 Hz

S-T segment monitoring: -2.0mV~2.0mV

Electrode drop indication: sound, light prompt

Scanning speed: 6.25, 12.5, 25, 50mm/sec

Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, auto

ECG calibration: 1mV+5%

Protective isolation withstands 4000V/AC/50Hz voltage;

ECG cable lead wire: 3/5 lead

Standard configuration: adult universal ECG cable

Optional configuration: ECG cable for children and newborns

Alarm: The upper and lower limits of the alarm value can be set and automatically memorized; there is an alarm review;

 

Blood oxygen saturation:

Display: blood oxygen value, pulse histogram, waveform, pulse value

Blood oxygen range: 0%-100% adult/child/newborn

Resolution: 1%

Accuracy: ±3% (Undefined below 70%)

Pulse rate:

Measuring range: 30~280bpm

Pulse accuracy: ±2bpm

Alarm range: 20~300bpm, the lower limit cannot be greater than the upper limit

sensor:

Standard configuration: adult soft finger ring

Optional configuration: soft finger ring for children, newborn strap

Alarm value: upper and lower limits can be set, automatic memory

 

 

Non-invasive blood pressure:

Measurement method: Oscillation method

Measurement parameters: systolic blood pressure, diastolic blood pressure, mean blood pressure

Working mode: manual, automatic, continuous measurement

Unit: mmHg/kPa optional

Measurement interval time of automatic measurement mode: 2.5~120min, ten-level adjustable

Overvoltage protection: software and hardware overvoltage protection

 Measuring range:

Adult Pediatric Newborn

Systolic blood pressure (mmHg) 40~255 40~200 40~135

Diastolic blood pressure (mmHg) 20~205 20~150 20~100

Average pressure (mmHg) 27~220 27~165 27~110

 

Cuff pressure range: 0-300 mmHg

Cuff:

Standard configuration: adult cuff

Select Configurations: Neonatal Cuff, Child Cuff

Alarm setting range:

Systolic blood pressure: 40~255mmHg, and the lower limit cannot be greater than the upper limit (adult),

        40~200mmHg, and the lower limit cannot be greater than the upper limit (children),

        40~135mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Diastolic blood pressure: 10~195mmHg, and the lower limit cannot be greater than the upper limit (adult),

        10~150mmHg, and the lower limit cannot be greater than the upper limit (in children),

        10~110mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Average pressure: 20~215mmHg, and the lower limit cannot be greater than the upper limit (adult),

        20~165mmHg, and the lower limit cannot be greater than the upper limit (in children),

        20~125mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Alarm display error: not more than ±5% of the set value.

 

Body temperature:

Body temperature measurement range: 0℃~50℃

Temperature measurement error: no more than ±0.1℃

Resolution: 0.1℃

Accuracy: ±0.1℃ (including sensor error)

Probe:

Standard configuration: permanent body temperature probe

Select configuration: esophageal temperature probe, rectal temperature probe.

Alarm value: upper and lower limits can be set, automatic memory

Alarm: All monitoring parameters can be set to alarm, and it has an alarm device that emits sound and light, and can cancel the alarm

 

Breathe:

Measurement method: thoracic impedance method

Respiratory rate measurement range and accuracy

Measuring range: adult: 0~ 120rpm;

          Pediatric/Neonatal: 0~150rpm.

Measurement accuracy: 10~150 rpm ±2 rpm or ±2%, whichever is greater;

            0~9 rpm is undefined.

Respiratory rate measurement resolution

Resolution: 1 rpm

Apnea alarm delay time

Can be set to: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s

Respiratory rate alarm limit range

Adult pediatric/neonatal alarm limit can be set as: 2~150rpm

 

Please Note: Accessories such as trolleys need to be purchased together with the machine, and additional shipping will be charged for separate purchases (estimated between 300-600 US dollars)

Product Comparison Chart for ICU Patient Monitors

Configuration/
Parameters
HM12
US$1299
HM11
US$1099
HM10
US$799
Display Size
13.3-inch
12.1-inch
12.1-inch
Display Resolution
1366*768
1280*800
1024*768
Screen
Capacitive Touch Screen
Non touch screen,
Capacitive Touch Screen Optional
Non touch screen,
 Resistive Touch Screen Optional
Multi-language
9
9
9
Lithium battery
Standard
Standard
Standard
Battery Life
7H
5H
5H
Screen Capture Function
Standard
Optional
Not Support
HDMI Output
Standard
Optional
Not Support
Parameter board
Fully discrete module
Six in one
Six in one
ECG Module
Independent
Integrated
Integrated
Blood Oxygen Module
Independent
Integrated
Integrated
Masimo SpO2
Optional
Optional
Not Support
Blood Pressure Module
Independent
Integrated
Integrated
Suntech Blood Pressure
Optional
Optional
Not Support
CO2 Mainstream
Support
Support
Support
CO2 By-Stream
Support
Support
Support
IBP Module
Optional
Not Support
Not Support
Nurse Call
Standard
Optional
Optional
Central Monitoring System
Optional
Optional
Optional
Internet Connection/LAN port
Support
Optional
Optional
ECG Leads
5 Leads 7 Leads
On The Same Screen
5 Leads 7 Leads
On The Same Screen
5 Leads 7 Leads
On The Same Screen
ECG Monitoring Range
15-350BPM
15-350BPM
15-350BPM
SpO2 Measurement Range
0%-100%
0%-100%
0%-100%
NIBP Measurement
0-300mmHg
0-300mmHg
0-300mmHg
History Review
1200H
1200H
960H
ECG Standards
AHA/IEC
AHA/IEC
AHA/IEC
Printing Module
Optional
Optional
Optional
WIFI
Optional
Optional
Optional
Net Weight
3.4Kg
3.25Kg
3.05Kg
Gross Weight
5.6Kg
5.4Kg
5.2Kg
Main unit Size
334±1Mm(L)*155±1Mm(D)*255±1Mm(H)
Overall Size
390±1Mm(L)*290±1Mm(D)*340±1Mm(H)