ICU CCU Ambulances Portable Vital Signs 6-Parameter Patient Monitor HM11 | DAWEI
ICU CCU Ambulances Portable Vital Signs 6-Parameter Patient Monitor HM11 | DAWEI
اتصل +8615305201757 ، إذا كنت بحاجة
ICU CCU Portable Vital Signs 6-Parameter ICU Monitor HM11
Standard configuration: ECG, blood oxygen, blood pressure, respiratory rate, body temperature, heart rate;
Optional configuration: printer, main stream/side stream ETCO2,WIFI.
One Set Accessories: five-lead wire*1, body surface temperature probe*1, blood oxygen probe*1, blood pressure extension tube*1, blood pressure cuff*1, power cord, disposable electrode pads*25 pieces;
Optional accessories: trolley, wall frame, etc.
Portable Vital Signs 6-Parameter Medical Monitor HM11 features: accurate data monitoring, timely alarm, multiple trend analysis.
-Support Multi-language, Chinese, English, Italian, Spanish, Turkish, Portuguese, Polish, Germany, Russian.
-Excellent clinical performance of blood oxygen: the accuracy of ±1bpm and the optimization algorithm present the value in seconds refresh response;
-Stable ECG waveform presentation, using mid-point low-resistance filtering method to ensure stable and effective waveform;
-Various alarm modes and parameter adjustment, comparable to the comprehensive performance of plug-in monitors.
1.1280*800 color LCD display, full viewing angle display, 10-level brightness adjustment freely;
- Tiled menu selection, clear at a glance, accurate response;
- Linux operating system, with more than 9 areas to display the distribution of parameters;
- The extremely short boot time is 10 seconds into the working state, and the emergency response is timely;
- More than six user-defined modes, special needs can also be met; save repeated operations;
- Rich and clear interface layout, quickly enter the setting field through classified display;
- Continue the operating habit, with parameter color adjustment function, the color of background, waveform and font can be customized according to needs;
- Operation interface in more than 5 languages; convenient operation of patient information entry\delete\save;
9. 20 kinds of arrhythmia event alarms, support ST segment analysis function;
- Trigger the printing function, record every abnormality in time; improve the communication efficiency between nurses and doctors (optional);
- Double overpressure protection of blood pressure software and hardware to ensure patient safety; six groups of data are displayed on the same screen, and trend analysis is clear at a glance;
- Equipped with: standard interface, large font, respiratory oxygenation diagram, coexistence of trends, seven-lead ECG on the same screen; (12-lead ECG on the same screen);
- International standard, sound and light double three-level alarm, safer and more professional;
- Super long alarm light, 360-degree visibility, easier to monitor patient status information;
- The alarm sound and the pulse rate sound are independent, the pulse rate sound continues to correspond when the alarm is muted, and the alarm sound can be activated normally when the pulse rate sound is muted;
- The waveform display has two ways of curve and filling to meet the needs of different departments;
- Large-capacity built-in lithium battery, continuous working time ≥ 300 minutes;
- When the waveform screen is frozen, the real-time parameters are continuously displayed in the parameter area; the frozen waveform can be viewed forward and backward along the time axis.
- Anti-defibrillation, electrosurgery, power grid, myoelectric interference;
- Low battery alarm, no data loss at critical moments;
- Large-capacity storage capacity: at least meet the data storage requirements of continuous patient monitoring for 1200 hours;
- Support fast import/export of USB configuration to meet the needs of different departments;
- Support USB external firmware upgrade, get rid of local restrictions;
- Support central monitoring system (optional);
- Support WIFI (optional) and other transmission functions;
- Mainstream/sidestream ETCO2 interface, support plug-and-play carbon dioxide module;
- Support thermal array recorder, three trace waveforms;
- The measurement/display unit is optional, truly understand the needs of different customers; (such as cm/inch, ℃/℉);
Standard parameters:
ECG:
Lead selection: three/five lead standard; up to 7 leads can be displayed on the same screen
I, II, III, AVR, AVL, AVF, V chest leads
ECG detection range: 15~350bpm
Resolution: 1bpm
Measurement accuracy: the greater of ±2% or ±2bpm
Frequency Response: 0.67Hz-40 Hz
S-T segment monitoring: -2.0mV~2.0mV
Electrode drop indication: sound, light prompt
Scanning speed: 6.25, 12.5, 25, 50mm/sec
Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, auto
ECG calibration: 1mV+5%
Protective isolation withstands 4000V/AC/50Hz voltage;
ECG cable lead wire: 3/5 lead
Standard configuration: adult universal ECG cable
Optional configuration: ECG cable for children and newborns
Alarm: The upper and lower limits of the alarm value can be set and automatically memorized; there is an alarm review;
Blood oxygen saturation:
Display: blood oxygen value, pulse histogram, waveform, pulse value
Blood oxygen range: 0%-100% adult/child/newborn
Resolution: 1%
Accuracy: ±3% (Undefined below 70%)
Pulse rate:
Measuring range: 30~280bpm
Pulse accuracy: ±2bpm
Alarm range: 20~300bpm, the lower limit cannot be greater than the upper limit
sensor:
Standard configuration: adult soft finger ring
Optional configuration: soft finger ring for children, newborn strap
Alarm value: upper and lower limits can be set, automatic memory
Non-invasive blood pressure:
Measurement method: Oscillation method
Measurement parameters: systolic blood pressure, diastolic blood pressure, mean blood pressure
Working mode: manual, automatic, continuous measurement
Unit: mmHg/kPa optional
Measurement interval time of automatic measurement mode: 2.5~120min, ten-level adjustable
Overvoltage protection: software and hardware overvoltage protection
Measuring range:
Adult Pediatric Newborn
Systolic blood pressure (mmHg) 40~255 40~200 40~135
Diastolic blood pressure (mmHg) 20~205 20~150 20~100
Average pressure (mmHg) 27~220 27~165 27~110
Cuff pressure range: 0-300 mmHg
Cuff:
Standard configuration: adult cuff
Select Configurations: Neonatal Cuff, Child Cuff
Alarm setting range:
Systolic blood pressure: 40~255mmHg, and the lower limit cannot be greater than the upper limit (adult),
40~200mmHg, and the lower limit cannot be greater than the upper limit (children),
40~135mmHg, and the lower limit cannot be greater than the upper limit (neonatal);
Diastolic blood pressure: 10~195mmHg, and the lower limit cannot be greater than the upper limit (adult),
10~150mmHg, and the lower limit cannot be greater than the upper limit (in children),
10~110mmHg, and the lower limit cannot be greater than the upper limit (neonatal);
Average pressure: 20~215mmHg, and the lower limit cannot be greater than the upper limit (adult),
20~165mmHg, and the lower limit cannot be greater than the upper limit (in children),
20~125mmHg, and the lower limit cannot be greater than the upper limit (neonatal);
Alarm display error: not more than ±5% of the set value.
Body temperature:
Body temperature measurement range: 0℃~50℃
Temperature measurement error: no more than ±0.1℃
Resolution: 0.1℃
Accuracy: ±0.1℃ (including sensor error)
Probe:
Standard configuration: permanent body temperature probe
Select configuration: esophageal temperature probe, rectal temperature probe.
Alarm value: upper and lower limits can be set, automatic memory
Alarm: All monitoring parameters can be set to alarm, and it has an alarm device that emits sound and light, and can cancel the alarm
Breathe:
Measurement method: thoracic impedance method
Respiratory rate measurement range and accuracy
Measuring range: adult: 0~ 120rpm;
Pediatric/Neonatal: 0~150rpm.
Measurement accuracy: 10~150 rpm ±2 rpm or ±2%, whichever is greater;
0~9 rpm is undefined.
Respiratory rate measurement resolution
Resolution: 1 rpm
Apnea alarm delay time
Can be set to: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Respiratory rate alarm limit range
Adult pediatric/neonatal alarm limit can be set as: 2~150rpm
Please Note: Accessories such as trolleys need to be purchased together with the machine, and additional shipping will be charged for separate purchases (estimated between 300-600 US dollars)
Product Comparison Chart for ICU Patient Monitors
Configuration/
Parameters
|
HM12
US$1299
|
HM11
US$1099
|
HM10
US$799
|
Display Size
|
13.3-inch
|
12.1-inch
|
12.1-inch
|
Display Resolution
|
1366*768
|
1280*800
|
1024*768
|
Screen
|
Capacitive Touch Screen
|
Non touch screen,
Capacitive Touch Screen Optional
|
Non touch screen,
Resistive Touch Screen Optional
|
Multi-language
|
9
|
9
|
9
|
Lithium battery
|
Standard
|
Standard
|
Standard
|
Battery Life
|
7H
|
5H
|
5H
|
Screen Capture Function
|
Standard
|
Optional
|
Not Support
|
HDMI Output
|
Standard
|
Optional
|
Not Support
|
Parameter board
|
Fully discrete module
|
Six in one
|
Six in one
|
ECG Module
|
Independent
|
Integrated
|
Integrated
|
Blood Oxygen Module
|
Independent
|
Integrated
|
Integrated
|
Masimo SpO2
|
Optional
|
Optional
|
Not Support
|
Blood Pressure Module
|
Independent
|
Integrated
|
Integrated
|
Suntech Blood Pressure
|
Optional
|
Optional
|
Not Support
|
CO2 Mainstream
|
Support
|
Support
|
Support
|
CO2 By-Stream
|
Support
|
Support
|
Support
|
IBP Module
|
Optional
|
Not Support
|
Not Support
|
Nurse Call
|
Standard
|
Optional
|
Optional
|
Central Monitoring System
|
Optional
|
Optional
|
Optional
|
Internet Connection/LAN port
|
Support
|
Optional
|
Optional
|
ECG Leads
|
5 Leads 7 Leads
On The Same Screen
|
5 Leads 7 Leads
On The Same Screen
|
5 Leads 7 Leads
On The Same Screen
|
ECG Monitoring Range
|
15-350BPM
|
15-350BPM
|
15-350BPM
|
SpO2 Measurement Range
|
0%-100%
|
0%-100%
|
0%-100%
|
NIBP Measurement
|
0-300mmHg
|
0-300mmHg
|
0-300mmHg
|
History Review
|
1200H
|
1200H
|
960H
|
ECG Standards
|
AHA/IEC
|
AHA/IEC
|
AHA/IEC
|
Printing Module
|
Optional
|
Optional
|
Optional
|
WIFI
|
Optional
|
Optional
|
Optional
|
Net Weight
|
3.4Kg
|
3.25Kg
|
3.05Kg
|
Gross Weight
|
5.6Kg
|
5.4Kg
|
5.2Kg
|
Main unit Size
|
334±1Mm(L)*155±1Mm(D)*255±1Mm(H)
|
||
Overall Size
|
390±1Mm(L)*290±1Mm(D)*340±1Mm(H)
|


