Patient monitor HM10 Technical Parameter

Technical parameter DOWNLOAD FILE

ECG:

Lead selection: three/five lead standard; up to 7 leads can be displayed on the same screen

I, II, III, AVR, AVL, AVF, V chest leads

ECG detection range: 15~350bpm

Resolution: 1bpm

Measurement accuracy: the greater of ±2% or ±2bpm

Frequency Response: 0.67Hz-40 Hz

S-T segment monitoring: -2.0mV~2.0mV

Electrode drop indication: sound, light prompt

Scanning speed: 6.25, 12.5, 25, 50mm/sec

Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, auto

ECG calibration: 1mV+5%

Protective isolation withstands 4000V/AC/50Hz voltage;

ECG cable lead wire: 3/5 lead

Standard configuration: adult universal ECG cable

Optional configuration: ECG cable for pediatric and neonatal

Alarm: The upper and lower limits of the alarm value can be set and automatically memorized; there is an alarm review;

 

Blood oxygen saturation:

Display: blood oxygen value, pulse histogram, waveform, pulse value

Blood oxygen range: 0%-100% adult/child/neonatal

Resolution: 1%

Accuracy: ±3% (Undefined below 70%)

Pulse rate:

Measuring range: 30~280bpm

Pulse accuracy: ±2bpm

Alarm range: 20~300bpm, the lower limit cannot be greater than the upper limit

Sensor:

Standard configuration: adult soft finger ring

Optional configuration: soft finger ring for pediatric, neonatal strap

Alarm value: upper and lower limits can be set, automatic memory

Non-invasive blood pressure(NIBP):

 Measurement method: Oscillation method

Measurement parameters: systolic blood pressure, diastolic blood pressure, mean blood pressure

Working mode: manual, automatic, continuous measurement

Unit: mmHg/kPa optional

Measurement interval time of automatic measurement mode: 2.5~120min, ten-level adjustable

Overvoltage protection: software and hardware overvoltage protection

 Measuring range:

Item

Adult

Pediatric

Neonatal

Systolic blood pressure (mmHg)

40~255

40~200

40~135

Diastolic blood pressure (mmHg)

20~205

20~150

20~100

Average pressure (mmHg)

27~220

27~165

27~110

 

Cuff pressure range: 0-300 mmHg

Cuff:

Standard configuration: adult cuff

Select Configurations: Neonatal Cuff, Child Cuff

Alarm setting range:

Systolic blood pressure: 40~255mmHg, and the lower limit cannot be greater than the upper limit (adult),

         40~200mmHg, and the lower limit cannot be greater than the upper limit (pediatric),

         40~135mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Diastolic blood pressure: 10~195mmHg, and the lower limit cannot be greater than the upper limit (adult),

         10~150mmHg, and the lower limit cannot be greater than the upper limit (pediatric),

         10~110mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Average pressure: 20~215mmHg, and the lower limit cannot be greater than the upper limit (adult),

         20~165mmHg, and the lower limit cannot be greater than the upper limit (pediatric),

         20~125mmHg, and the lower limit cannot be greater than the upper limit (neonatal);

Alarm display error: not more than ±5% of the set value.

 

Temperature:

 Temperature measurement range: 0℃~50℃

Temperature measurement error: no more than ±0.1℃

Resolution: 0.1℃

Accuracy: ±0.2°C (including sensor error)

Probe:

Standard configuration: permanent body temperature probe

Select configuration: esophageal temperature probe, rectal temperature probe.

Alarm value: upper and lower limits can be set, automatic memory

Alarm: All monitoring parameters can be set to alarm, and it has an alarm device that emits sound and light, and can cancel the alarm

 

Breath measurement:

Measurement method: thoracic impedance method

Respiratory rate measurement range and accuracy

Measuring range: adult: 0~ 120rpm;

           Pediatric/Neonatal: 0~150rpm.

Measurement accuracy: 10~150 rpm ±2 rpm or ±2%, whichever is greater;

             0~9 rpm is undefined.

Respiratory rate measurement resolution

Resolution: 1 rpm

Apnea alarm delay time

Can be set to: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s

Respiratory rate alarm limit range

Adult pediatric/neonatal alarm limit can be set as: 2~150rpm