Phone wireless ultrasound probe - Parameters
Technical Sheets DOWNLOAD FILE
Parameters of wireless handheld color Doppler ultrasound Probe |
||
1 |
configure: |
One probe and one set of wireless charger |
2 |
hardware requirements
|
IOS version Processor dominant frequency: ≥ 1.8GHz, Memory: ≥ 2G, Display screen: ≥ 9.7 inch, Screen resolution: ≥ 2048x1536, Brightness: with ambient light detection function and display brightness correction function Operating system: iOS12.3 or above Network protocol needs to be compatible with 802.11n protocol |
Android version Processor dominant frequency: ≥ 22GHz, processor model: ≥ Qualcomm Snapdragon 660AIE, Memory: ≥ 4G, Display screen: ≥ 8 inches, Screen resolution: ≥ 1920x1200, Brightness: with ambient light detection function and display brightness correction function Operating system: Android version 8.1.0 or above Network protocol needs to be compatible with 802.11n protocol |
||
3 |
advantage |
Easy to operate and carry, it can be used in various clinical scenes; WiFi connection, get rid of wire bondage; 15 meters away, no signal attenuation; Wireless charging, ready to use; |
4 |
Scope of application |
It is applicable to medical and health institutions such as hospitals, clinics, disease control centers, clinical testing centers, health care centers, first aid stations, nursing stations, ambulances, nursing homes, childcare centers, plastic and aesthetic institutions, etc. at all levels and in various types of hospitals, clinics, disease control centers, clinical testing centers, health care centers, first aid stations, nursing stations, etc. It is used for human clinical ultrasonic examination, including ultrasonic examination of abdomen, superficial organs, peripheral blood vessels, etc. |
5 |
Performance introduction: |
|
5.1 |
Scanning mode |
Convex array/linear array |
5.2 |
pattern |
B、B/M、CFM、PDI、PW |
5.3 |
Check presets |
Convex array: abdomen, gynecology, obstetrics, heart, urinary system, kidney, lung Linear array: thyroid, small organs, pediatrics, blood vessels, carotid arteries, breast, musculoskeletal, nerves Micro convex: heart, abdomen Phased array: heart, abdomen |
5.4 |
Measurement method |
General measurement: length, area/perimeter, trajectory, depth, angle Obstetric measurement: head hip length, biparietal diameter, gestational sac diameter, femoral length, head circumference, abdominal circumference, fetal weight (biparietal diameter), fetal weight (femoral length) B/M measurement: heart rate (2), duration, distance, LVID measurement PW measurement: speed, S/D, heart rate (2), depth |
5.5 |
Number of movie playback frames |
100/200/500/1000 |
5.6 |
B mode parameters: |
|
5.6.1 |
Gain GN |
Range: G30 - G105; |
5.6.2 |
Depth D |
Convex array 90mm-305mm Linear array 20mm-100mm Slightly convex 30mm-120mm Phased array 90mm-190mm |
5.6.3 |
Image Enhancement (SRI) |
0-4, 5 |
5.6.4 |
focus |
2 focus points, 4 groups of positions in total, 1 focus point for convex array probe; |
5.6.5 |
puncture |
There are two kinds of puncture auxiliary functions: In Plane (in-plane guide line) Out Plane |
5.6.6 |
frequency |
DW-X1: 2-segment frequency conversion, convex array 3.2MHz-5.0HMz, linear array 7.5MHz-10.0HMz DW-C1:2 section frequency conversion, 3.2MHz-5.0HMz DW-L1:2 section frequency conversion, 7.5MHz-10.0HMz DW-L2: 2-section frequency conversion, 10.0MHz-14.0HMz DW-C2: 2-section frequency conversion, 6.5MHz-8.0HMz DW-P1:2 section frequency conversion, 2.2MHz-3.6HMz |
5.7 |
CFM mode parameters: |
|
5.7.1 |
Color Gain |
Color gain, range 0-100; |
5.7.2 |
Scale(PRF) |
Pulse repetition frequency, 4 groups in total: 1.25K, 2.0K, 3.2K and 4.0K for linear array; The convex matrix is 1.25K, 1.6K, 2.5K, 3.2K; |
5.7.3 |
Wall filtering |
0-15, 16 gears in total; |
5.7.4 |
Red blue flip |
Color code flipping; |
5.7.5 |
Deflection angle (Steer) |
Three groups of angles: - 12, 0,+12 |
5.8 |
PW mode parameters: |
|
5.8.1 |
PW Gain |
PW gain, range 0-100; |
5.8.2 |
Sampling volume |
The sampling volume is 1mm 2mm 5mm; |
5.8.3 |
Deflection angle |
Sampling line angle, 5 groups of angles in total: - 12, - 7, 0,+7,+12; |
5.8.4 |
Correction angle |
Sampling gate angle,+60 degrees, 0, - 60 degrees. |
5.8.5 |
Scale(PRF) |
Pulse repetition frequency, 4 groups in total: The convex matrix is 1.25K, 1.6K, 2.5K, 3.2K; 1.25K, 2.0K, 3.2K and 4.0K for linear array; Slightly convex: 1.25K, 2.0K, 3.2K, 4.0K; The phased array is 2.0K, 2.5K, 3.2K, 4.0K; |
5.8.6 |
Correction angle |
Sampling gate angle, - 85 ° to 85 °, step 5; |
6 |
other |
|
6.1 |
Measurement aids |
Measuring magnifier |
6.2 |
DICOM |
Transferable |
6.3 |
notes |
Text annotation |
6.4 |
Save Video |
MP4, up to 1000 frames (≈ 77 seconds) |
6.5 |
Save Picture |
JPG 、 DICOM |
6.6 |
Usage time |
≈ 2 hours |
6.7 |
Battery capacity |
1350mAh |
6.8 |
size |
DW-X1:123mm*52.6mm*22mm DW-C1:116mm*71mm*22mm DW-L1:115mm*65mm*22mm DW-L2:114mm*52mm*21mm DW-C2:132mm*52mm*23mm DW-P1:127mm*52mm*23mm |
6.9 |
weight |
95-125g |